P12-1S

Minimum Rating
11 kVA / 11 kW

Maximum Rating
12 kVA / 12 kW

Emissions/Fuel Strategy
Fuel Optimised


SKU: 38da40b46a65 Categories: ,

Full Specifications

Generator Set Specifications

Minimum Rating 11 kVA / 11 kW
Maximum Rating 12 kVA / 12 kW
Emissions/Fuel Strategy Fuel Optimised
50 Hz Prime 11 kVA / 11 kW
50 Hz Standby 12 kVA / 12 kW
60 Hz Prime – / –
60 Hz Standby
Frequency 50 Hz
Speed 1500 RPM
Voltage 220-240 Volts
50 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
60 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
50 Hz Standby Rating Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

Engine Specifications

Engine Model Perkins® 403A-15G2
Bore 84.0 mm (3.3 in)
Stroke 90.0 mm (3.5 in)
Governor Type Mechanical
Displacement 1.5L (91.3 cu. in)
Compression Ratio 22.5:01

Benefits & Features

The Story

The 6.8 – 25 kVA range of generator sets is designed to power your every need. With an enhanced choice of power nodes, this range is engineered for optimum performance in diverse applications including construction, residential, retail and telecommunications. The contemporary design of the polymer enclosure option redefines durability in the marketplace and further enhances this range alongside the more traditional metal enclosure. For a life without interruptions, trust FG Wilson.

 

Industry Leading Perkins Engine

The 400 Series engines offer highly competitive performance, fuel economy and EUIIIa Emissions compliance on selected nodes. These engines have been designed to be reliable and to offer low cost of ownership in the wide variety of markets they serve.

Alternator

Benefiting from the well-established Leroy Somer alternator, known worldwide for providing power generation expertise and solutions offering longlife products with low maintenance

 

Deep Sea DSE4520

The DSE4520 is a compact Auto Mains (Utility) Failure Control Module that has been developed to provide an outstanding range of features within a compact enclosure. Monitoring engine speed, oil pressure, coolant temperature, frequency, voltage, current, power and fuel level, the modules will give comprehensive engine and alternator protection. This will be indicated on a large back-lit LCD icon display via an array of warning, electrical trip and shutdown alarms.

Single-Source Supplier

Fully prototype tested with certified torsional vibration analysis available

 

World Wide Product Support

FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.

 

Standard Reference Conditions

Prime Rating – These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating – These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

Optional Equipment

Exhaust

  • Industrial

Control Panels

  • Deep Sea DSE7410
  • Deep Sea DSE7420

Starting/Charging

  • Lead Acid battery (Dry)

General

  • Upgrade to Standard Set for “CE” Certification
  • EEC Declaration of Conformity
  • 8 Hour, 600L, 1000L, 2000L fuel tanks
  • Level 1, 2, 3 Sound attenuated, galvanised steel enclosure
  • Dual wall fuel tanks

Standard Equipment

Engine

  • Air Cleaner
  • Lube oil drain valve
  • Engine filled with lubrication oil
  • High Coolant Temperature Shutdown
  • Low Oil Pressure Shutdown

Cooling

  • Package mounted radiator
  • Radiator & Cooling Fan
  • Coolant Drain Valve
  • Fan, Fan drive and battery charging Alternator drive fully guarded to meet EC Machinery Directive
  • Cooling System filled with Coolant mix

Exhaust

  • Exhaust flange outlet
  • Exhaust stub pipe and gasket

Alternator

  • Leroy Somer
  • SHUNT Excitation
  • IP23 Protection

Control Panel

  • DeepSea 4520

Mounting

  • Skid Base, Formed Steel
  • Certified Base Mounted Lifting Eyes, and Rear Drag Eyelets
  • Anti-vibration mounts
  • Battery Tray and Cables